Genius Moves by Brother of Manager!
What was the challenge?
Suppose you are the brother of that manager & have accepted the challenge.
For sake of convenience, we will name switches inside the room operating machines as an 'operating switches' & those which are outside the room as a 'back up switches'.
Though windowless, we assume that operating sound of machine(s) can be heard from outside room but can't see which machine(s) is (are) in operating condition.
Here is what you should do!
1. Let's label the machines which we are going to keep ON as ACTIVE & others as INACTIVE.
2. Turn off operating switches of 2 machines so that there are three machine ACTIVE and two are INACTIVE inside the room.
3. Go outside and now your task is to find the 3 back up switches controlling 3 active machines inside the room.
4. You have to switch off three switches in all possible combinations. There are 10 such possible combinations (5C3) of 3 controlling switches out of 5.
5. If 0 represents OFF position and 1 represents ON position then you should try all possible below combination.
11000
10100
10010
10001
01100
01010
01001
00110
00101
00011
6. There will be exactly one combination in which all three ACTIVE machines will be OFF & there will be no sound coming out of the room. The three switches having value of 0 are controlling ACTIVE machines while other 2 must be controlling INACTIVE machines.
7. Still we don't know the exact switch operating the each machine. Label 3 switches controlling ACTIVE machines as A, B and C & those controlling INACTIVE machines as D & E.
Allow some time to cool down all those ACTIVE machines.
8. Now, turn on 2 switches A & B and keep switch E ON. Machines connected to A and B will start working.
9. After a while, turn off the switch B and go inside the room.
10. The machine which is still operating must be controlled by back up switch A.
11. Touch other 2 which were labelled as ACTIVE & check which has got warmer.
12. The machine which is warmer must be controlled by back up switch B.
13. And since we didn't turn on the switch C (after giving time all to cool down), the machine having normal temperature must be controlled by the switch C.
14. Remember, we had turned off operating switches of INACTIVE machines initially. And before entering into room again we have turned on switch E.
15. Now, turn on operating switch of one of the INACTIVE labelled machine.
If the machine starts working it must be connected to the switch E & other to the switch D. And if the machine doesn't start working it must be connected to D & other to E.
This way, you will find every back up switch located outside the room controlling operating switch of each machine inside the room.
Comments
Post a Comment